Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
2.
4.
Rev Esp Cardiol (Engl Ed) ; 73(5): 408, 2020 May.
Artigo em Inglês, Espanhol | MEDLINE | ID: mdl-32381259
6.
Cardiology ; 143(1): 52-61, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-31307038

RESUMO

PURPOSE: Left ventricular (LV) mechanics are impaired in patients with severe aortic stenosis (AS). Transcatheter aortic valve replacement (TAVR) has become a widespread technique for patients with severe AS considered inoperable or high risk for open surgery. This procedure could have a positive impact in LV mechanics. The aim of the study was to evaluate the effect of TAVR on LV function recovery, as assessed by myocardial deformation parameters, both immediately and in the long term. METHODS: One-hundred nineteen consecutive patients (81.2 ± 6.9 years, 50.4% female) from 10 centres in Europe with severe AS who successfully underwent TAVR with either a self-expanding CoreValve (Medtronic, Minneapolis, MN, USA) or a mechanically expanded Lotus valve (Boston Scientific, Natick, MA, USA) were enrolled in a prospective observational study. A complete echocardiographic examination was performed prior to device implantation, before discharge and 1 year after the procedure, including the assessment of LV strain using standard 2D images. RESULTS: Between baseline and discharge, only a modest but statistically significant improvement in GLS (global longitudinal strain) could be seen (GLS% -14.6 ± 5.0 at baseline; -15.7 ± 5.1 at discharge, p = 0.0116), although restricted to patients in the CoreValve group; 1 year after the procedure, a greater improvement in GLS was observed (GLS% -17.1 ± 4.9, p < 0.001), both in the CoreValve and the Lotus groups. CONCLUSIONS: Immediate and sustained improvement in GLS was appreciated after the TAVR procedure. Whether this finding continues to be noted in a more prolonged follow-up and its clinical implications need to be assessed in further studies.


Assuntos
Estenose da Valva Aórtica/cirurgia , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Disfunção Ventricular Esquerda/terapia , Idoso de 80 Anos ou mais , Estenose da Valva Aórtica/complicações , Ecocardiografia , Feminino , Ventrículos do Coração/diagnóstico por imagem , Humanos , Masculino , Estudos Prospectivos , Disfunção Ventricular Esquerda/etiologia
7.
Cardiol J ; 25(4): 487-494, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-29924376

RESUMO

BACKGROUND: Left ventricular (LV) mechanics are impaired in patients with severe aortic stenosis (AS). Transcatheter aortic valve replacement (TAVR) has become a widespread technique for patients with severe AS considered inoperable or high risk for traditional open-surgery. This procedure could have a positive impact in LV mechanics. The aim of this study was to evaluate the immediate effect of TAVR on LV function recovery, as assessed by myocardial deformation parameters. METHODS: One-hundred twelve consecutive patients (81.4 ± 6.4 years, 50% female) from 10 centres in Europe with severe AS who successfully underwent TAVR with either a self-expanding CoreValve (Medtronic, Minneapolis, MN) or a mechanically expanded Lotus valve (Boston Scientific, Natick, MA) were enrolled in a prospective multi-center study. A complete echocardiographic examination was performed at baseline and immediately before discharge, including the assessment of LV strain using standard two-dimensional images. RESULTS: Echocardiographic examination with global longitudinal strain (GLS) quantification could be obtained in 92 patients, because of echocardiographic and logistic reasons. Between examinations, a modest statistically significant improvement in GLS could be seen (GLS% -15.00 ± 4.80 at baseline;-16.15 ± 4.97 at discharge, p = 0.028). In a stratified analysis, only women showed a significant improvement in GLS and a trend towards greater improvement in GLS according to severity of systolic dysfunction as measured by LV ejection fraction could be noted. CONCLUSIONS: Immediate improvement in GLS was appreciated after TAVR procedure. Whether this finding continues to be noted in a more prolonged follow-up and its clinical implications need to be assessed in further studies.


Assuntos
Estenose da Valva Aórtica/cirurgia , Ventrículos do Coração/fisiopatologia , Substituição da Valva Aórtica Transcateter/métodos , Função Ventricular Esquerda/fisiologia , Idoso de 80 Anos ou mais , Estenose da Valva Aórtica/diagnóstico , Estenose da Valva Aórtica/fisiopatologia , Ecocardiografia , Feminino , Seguimentos , Ventrículos do Coração/diagnóstico por imagem , Humanos , Masculino , Período Pós-Operatório , Estudos Prospectivos , Índice de Gravidade de Doença , Fatores de Tempo , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...